Peak Sun Hours in Ankara, Ankara, Turkey

4.7
kWh/m²/day (annual avg)
Solar zone
Zone 3 (good)
Best month
July (7.7)
Worst month
December (1.7)
Climate
Temperate · 10.3°C

Monthly solar breakdown

J: 1.94 kWh/m²/day F: 2.9 kWh/m²/day M: 4.15 kWh/m²/day A: 5.45 kWh/m²/day M: 6.46 kWh/m²/day J: 7.35 kWh/m²/day J: 7.66 kWh/m²/day A: 6.82 kWh/m²/day S: 5.43 kWh/m²/day O: 3.72 kWh/m²/day N: 2.54 kWh/m²/day D: 1.73 kWh/m²/day J F M A M J J A S O N D 9 0
Month GHI Clear-sky DNI DHI Temp °C Humid %
Jan 1.94 3.04 2.45 1.05 -2.1 87
Feb 2.90 4.16 3.15 1.47 0.3 81
Mar 4.15 5.61 3.95 1.90 4.2 73
Apr 5.45 7.00 4.56 2.41 8.9 67
May 6.46 7.95 5.26 2.68 14.2 64
Jun 7.35 8.41 6.87 2.44 18.6 59
Jul 7.66 8.16 7.93 2.11 22.2 49
Aug 6.82 7.22 7.29 1.92 22.5 47
Sep 5.43 5.96 6.25 1.67 18.0 51
Oct 3.72 4.45 4.65 1.40 11.9 63
Nov 2.54 3.25 3.93 0.99 5.1 73
Dec 1.73 2.66 2.55 0.87 -0.1 84

GHI, Clear-sky, DNI, DHI in kWh/m²/day. Data: NASA POWER climatology (long-term monthly averages).

Off-grid calculator

Add appliances

  • Add an appliance to size a system.

Sizing

Daily load
0.00 kWh
Panel wattage
0 W
Panel count (400W modules)
0
Battery bank
0.0 kWh

Sizing against worst-month PSH of 1.73 kWh/m²/day, 0.77 system efficiency.

About solar in Ankara

Ankara, Turkey has a temperate climate with meaningful seasonal variation in solar resource. Its annual peak sun hours average 4.68 kWh/m²/day, a good solar resource by global standards.

The strongest month in Ankara is July (summer) at 7.66 kWh/m²/day, and the weakest is December (winter) at 1.73 kWh/m²/day. When sizing a year-round off-grid system, it's standard practice to design against the December value rather than the annual average — otherwise the battery bank runs low during the darkest weeks.

Ankara's solar conditions are well within the range where off-grid PV is a straightforward engineering exercise with standard-sized arrays and lithium batteries.

FAQ

What are the peak sun hours in Ankara?
Ankara averages 4.68 peak sun hours per day annually, ranging from 1.73 in December to 7.66 in July.
How many solar panels do I need in Ankara?
Panel count depends on your daily load. At Ankara's annual average of 4.68 kWh/m²/day, a 5 kWh/day load needs roughly 4 × 400 W panels. Use the calculator above for your actual load.
What size battery do I need in Ankara?
Sizing against Ankara's worst month (December, 1.73 kWh/m²/day) with 2 days of autonomy at 80% depth of discharge, a 5 kWh/day load needs about a 12.5 kWh battery bank.
How does Ankara's solar resource compare globally?
Ankara sits in solar zone 3 out of 5 (where 5 is strongest) at 4.68 kWh/m²/day — good by global standards. For reference, top-tier desert sites average ~6.5 and high-latitude cities around 2.5 kWh/m²/day.
How much does winter reduce solar output in Ankara?
Ankara's worst month (December) delivers 1.73 kWh/m²/day — about 23% of the summer peak of 7.66. Off-grid systems here typically oversize 1.5–2× or pair with a backup source.
Do cloudy days significantly affect Ankara's solar?
Partly. Diffuse light still produces 10–25% of clear-sky output. Ankara's 4.68 kWh/m²/day already reflects average cloudiness, so no further derating is needed for sizing.
What panel tilt works best in Ankara?
At Ankara's latitude (40°), a fixed tilt near 40° balances year-round yield. Winter-heavy loads favor latitude + 15°; summer-heavy, latitude − 15°.