Peak Sun Hours in Dera Ghazi Khan, Punjab, Pakistan

5.1
kWh/m²/day (annual avg)
Solar zone
Zone 4 (excellent)
Best month
May (6.8)
Worst month
December (3.1)
Climate
Arid · 27.4°C

Monthly solar breakdown

J: 3.29 kWh/m²/day F: 4.16 kWh/m²/day M: 5.3 kWh/m²/day A: 6.36 kWh/m²/day M: 6.85 kWh/m²/day J: 6.57 kWh/m²/day J: 5.93 kWh/m²/day A: 5.7 kWh/m²/day S: 5.46 kWh/m²/day O: 4.66 kWh/m²/day N: 3.56 kWh/m²/day D: 3.15 kWh/m²/day J F M A M J J A S O N D 8 0
Month GHI Clear-sky DNI DHI Temp °C Humid %
Jan 3.29 3.68 3.65 1.44 13.8 33
Feb 4.16 4.69 4.09 1.72 17.0 34
Mar 5.30 5.92 4.46 2.19 23.1 32
Apr 6.36 6.98 4.93 2.52 29.7 26
May 6.85 7.38 4.73 2.87 35.4 19
Jun 6.57 7.12 3.78 3.11 37.9 27
Jul 5.93 6.54 2.79 3.18 37.5 36
Aug 5.70 6.32 3.11 2.91 36.0 39
Sep 5.46 5.81 4.02 2.38 33.2 33
Oct 4.66 4.78 4.06 1.96 27.8 23
Nov 3.56 3.73 3.64 1.56 21.1 26
Dec 3.15 3.37 3.78 1.32 15.9 29

GHI, Clear-sky, DNI, DHI in kWh/m²/day. Data: NASA POWER climatology (long-term monthly averages).

Off-grid calculator

Add appliances

  • Add an appliance to size a system.

Sizing

Daily load
0.00 kWh
Panel wattage
0 W
Panel count (400W modules)
0
Battery bank
0.0 kWh

Sizing against worst-month PSH of 3.15 kWh/m²/day, 0.77 system efficiency.

About solar in Dera Ghazi Khan

Dera Ghazi Khan, Pakistan has a dry climate with long hours of direct sunshine and low humidity. Its annual peak sun hours average 5.08 kWh/m²/day, a excellent solar resource by global standards.

The strongest month in Dera Ghazi Khan is May (spring) at 6.85 kWh/m²/day, and the weakest is December (winter) at 3.15 kWh/m²/day. When sizing a year-round off-grid system, it's standard practice to design against the December value rather than the annual average — otherwise the battery bank runs low during the darkest weeks.

Dera Ghazi Khan's solar conditions are well within the range where off-grid PV is a straightforward engineering exercise with standard-sized arrays and lithium batteries.

FAQ

What are the peak sun hours in Dera Ghazi Khan?
Dera Ghazi Khan averages 5.08 peak sun hours per day annually, ranging from 3.15 in December to 6.85 in May.
How many solar panels do I need in Dera Ghazi Khan?
Panel count depends on your daily load. At Dera Ghazi Khan's annual average of 5.08 kWh/m²/day, a 5 kWh/day load needs roughly 4 × 400 W panels. Use the calculator above for your actual load.
What size battery do I need in Dera Ghazi Khan?
Sizing against Dera Ghazi Khan's worst month (December, 3.15 kWh/m²/day) with 2 days of autonomy at 80% depth of discharge, a 5 kWh/day load needs about a 12.5 kWh battery bank.
How does Dera Ghazi Khan's solar resource compare globally?
Dera Ghazi Khan sits in solar zone 4 out of 5 (where 5 is strongest) at 5.08 kWh/m²/day — excellent by global standards. For reference, top-tier desert sites average ~6.5 and high-latitude cities around 2.5 kWh/m²/day.
How often should I clean solar panels in Dera Ghazi Khan?
Arid climates can drop output 10–20% between cleanings. Quarterly cleaning is typical for Dera Ghazi Khan; monthly during dust-storm seasons. Dew alone isn't enough when rainfall is infrequent.
Does extreme heat hurt solar output in Dera Ghazi Khan?
Yes. Panel efficiency drops ~0.4% per °C above 25 °C cell temperature. In Dera Ghazi Khan, midday cell temperatures of 55–70 °C can derate output 12–18% below nameplate.
Is Dera Ghazi Khan's solar resource as strong as the numbers suggest?
Dera Ghazi Khan's 5.08 kWh/m²/day is excellent globally. But heat derating and dust accumulation mean real-world yields typically land 10–15% below this headline figure — factor that into sizing.