Peak Sun Hours in Kagoshima, Kagoshima, Japan

4.0
kWh/m²/day (annual avg)
Solar zone
Zone 2 (moderate)
Best month
August (5.4)
Worst month
December (2.3)
Climate
Temperate · 18.0°C

Monthly solar breakdown

J: 2.4 kWh/m²/day F: 3.08 kWh/m²/day M: 4.09 kWh/m²/day A: 4.84 kWh/m²/day M: 4.99 kWh/m²/day J: 4.17 kWh/m²/day J: 5.3 kWh/m²/day A: 5.43 kWh/m²/day S: 4.53 kWh/m²/day O: 3.85 kWh/m²/day N: 2.85 kWh/m²/day D: 2.27 kWh/m²/day J F M A M J J A S O N D 6 0
Month GHI Clear-sky DNI DHI Temp °C Humid %
Jan 2.40 3.74 2.72 1.20 8.5 77
Feb 3.08 4.66 2.96 1.47 9.8 76
Mar 4.09 5.88 3.45 1.86 12.3 75
Apr 4.84 6.91 3.56 2.23 16.2 76
May 4.99 7.54 3.10 2.53 20.1 79
Jun 4.17 7.65 1.96 2.45 23.2 85
Jul 5.30 7.61 3.71 2.48 26.7 86
Aug 5.43 7.11 4.21 2.40 27.5 82
Sep 4.53 6.23 3.74 2.04 25.3 81
Oct 3.85 5.08 3.84 1.62 20.7 77
Nov 2.85 3.97 3.22 1.28 15.7 76
Dec 2.27 3.45 2.77 1.11 10.6 77

GHI, Clear-sky, DNI, DHI in kWh/m²/day. Data: NASA POWER climatology (long-term monthly averages).

Off-grid calculator

Add appliances

  • Add an appliance to size a system.

Sizing

Daily load
0.00 kWh
Panel wattage
0 W
Panel count (400W modules)
0
Battery bank
0.0 kWh

Sizing against worst-month PSH of 2.27 kWh/m²/day, 0.77 system efficiency.

About solar in Kagoshima

Kagoshima, Japan has a temperate climate with meaningful seasonal variation in solar resource. Its annual peak sun hours average 3.98 kWh/m²/day, a moderate solar resource by global standards.

The strongest month in Kagoshima is August (summer) at 5.43 kWh/m²/day, and the weakest is December (winter) at 2.27 kWh/m²/day. When sizing a year-round off-grid system, it's standard practice to design against the December value rather than the annual average — otherwise the battery bank runs low during the darkest weeks.

Given the moderate resource, Kagoshima installations typically oversize panels or combine solar with another source (grid, generator, hydro) for reliability.

FAQ

What are the peak sun hours in Kagoshima?
Kagoshima averages 3.98 peak sun hours per day annually, ranging from 2.27 in December to 5.43 in August.
How many solar panels do I need in Kagoshima?
Panel count depends on your daily load. At Kagoshima's annual average of 3.98 kWh/m²/day, a 5 kWh/day load needs roughly 5 × 400 W panels. Use the calculator above for your actual load.
What size battery do I need in Kagoshima?
Sizing against Kagoshima's worst month (December, 2.27 kWh/m²/day) with 2 days of autonomy at 80% depth of discharge, a 5 kWh/day load needs about a 12.5 kWh battery bank.
How does Kagoshima's solar resource compare globally?
Kagoshima sits in solar zone 2 out of 5 (where 5 is strongest) at 3.98 kWh/m²/day — moderate by global standards. For reference, top-tier desert sites average ~6.5 and high-latitude cities around 2.5 kWh/m²/day.
How much does winter reduce solar output in Kagoshima?
Kagoshima's worst month (December) delivers 2.27 kWh/m²/day — about 42% of the summer peak of 5.43. Off-grid systems here typically oversize 1.5–2× or pair with a backup source.
Do cloudy days significantly affect Kagoshima's solar?
Partly. Diffuse light still produces 10–25% of clear-sky output. Kagoshima's 3.98 kWh/m²/day already reflects average cloudiness, so no further derating is needed for sizing.
What panel tilt works best in Kagoshima?
At Kagoshima's latitude (32°), a fixed tilt near 32° balances year-round yield. Winter-heavy loads favor latitude + 15°; summer-heavy, latitude − 15°.