Peak Sun Hours in São Bernardo do Campo, São Paulo, Brazil

4.5
kWh/m²/day (annual avg)
Solar zone
Zone 3 (good)
Best month
December (5.5)
Worst month
June (3.3)
Climate
Temperate · 19.6°C

Monthly solar breakdown

J: 5.23 kWh/m²/day F: 5.44 kWh/m²/day M: 4.91 kWh/m²/day A: 4.36 kWh/m²/day M: 3.52 kWh/m²/day J: 3.26 kWh/m²/day J: 3.48 kWh/m²/day A: 4.15 kWh/m²/day S: 4.42 kWh/m²/day O: 4.91 kWh/m²/day N: 5.23 kWh/m²/day D: 5.49 kWh/m²/day J F M A M J J A S O N D 7 0
Month GHI Clear-sky DNI DHI Temp °C Humid %
Jan 5.23 8.21 2.98 2.65 22.3 83
Feb 5.44 7.75 3.75 2.40 22.4 83
Mar 4.91 6.86 3.75 2.14 21.6 85
Apr 4.36 5.76 4.15 1.73 20.0 84
May 3.52 4.76 3.90 1.41 17.1 84
Jun 3.26 4.22 4.02 1.20 16.3 82
Jul 3.48 4.48 4.40 1.13 15.9 79
Aug 4.15 5.32 4.77 1.29 17.2 75
Sep 4.42 6.22 3.94 1.69 19.1 73
Oct 4.91 7.31 3.52 2.19 20.7 75
Nov 5.23 8.13 3.36 2.53 20.9 79
Dec 5.49 8.35 3.29 2.73 22.1 81

GHI, Clear-sky, DNI, DHI in kWh/m²/day. Data: NASA POWER climatology (long-term monthly averages).

Off-grid calculator

Add appliances

  • Add an appliance to size a system.

Sizing

Daily load
0.00 kWh
Panel wattage
0 W
Panel count (400W modules)
0
Battery bank
0.0 kWh

Sizing against worst-month PSH of 3.26 kWh/m²/day, 0.77 system efficiency.

About solar in São Bernardo do Campo

São Bernardo do Campo, Brazil has a temperate climate with meaningful seasonal variation in solar resource. Its annual peak sun hours average 4.53 kWh/m²/day, a good solar resource by global standards.

The strongest month in São Bernardo do Campo is December (summer) at 5.49 kWh/m²/day, and the weakest is June (winter) at 3.26 kWh/m²/day. When sizing a year-round off-grid system, it's standard practice to design against the June value rather than the annual average — otherwise the battery bank runs low during the darkest weeks.

São Bernardo do Campo's solar conditions are well within the range where off-grid PV is a straightforward engineering exercise with standard-sized arrays and lithium batteries.

FAQ

What are the peak sun hours in São Bernardo do Campo?
São Bernardo do Campo averages 4.53 peak sun hours per day annually, ranging from 3.26 in June to 5.49 in December.
How many solar panels do I need in São Bernardo do Campo?
Panel count depends on your daily load. At São Bernardo do Campo's annual average of 4.53 kWh/m²/day, a 5 kWh/day load needs roughly 4 × 400 W panels. Use the calculator above for your actual load.
What size battery do I need in São Bernardo do Campo?
Sizing against São Bernardo do Campo's worst month (June, 3.26 kWh/m²/day) with 2 days of autonomy at 80% depth of discharge, a 5 kWh/day load needs about a 12.5 kWh battery bank.
How does São Bernardo do Campo's solar resource compare globally?
São Bernardo do Campo sits in solar zone 3 out of 5 (where 5 is strongest) at 4.53 kWh/m²/day — good by global standards. For reference, top-tier desert sites average ~6.5 and high-latitude cities around 2.5 kWh/m²/day.
How much does winter reduce solar output in São Bernardo do Campo?
São Bernardo do Campo's worst month (June) delivers 3.26 kWh/m²/day — about 59% of the summer peak of 5.49. Off-grid systems here typically oversize 1.5–2× or pair with a backup source.
Do cloudy days significantly affect São Bernardo do Campo's solar?
Partly. Diffuse light still produces 10–25% of clear-sky output. São Bernardo do Campo's 4.53 kWh/m²/day already reflects average cloudiness, so no further derating is needed for sizing.
What panel tilt works best in São Bernardo do Campo?
At São Bernardo do Campo's latitude (24°), a fixed tilt near 24° balances year-round yield. Winter-heavy loads favor latitude + 15°; summer-heavy, latitude − 15°.