peaksunhours.app

Peak Sun Hours in Duque de Caxias, Rio de Janeiro, Brazil

4.7
kWh/m²/day (annual avg)
Solar zone
Zone 3 (good)
Best month
February (6.0)
Worst month
June (3.5)
Climate
Tropical · 23.4°C

Monthly solar breakdown

J: 5.78 kWh/m²/day F: 5.97 kWh/m²/day M: 5.14 kWh/m²/day A: 4.52 kWh/m²/day M: 3.68 kWh/m²/day J: 3.46 kWh/m²/day J: 3.64 kWh/m²/day A: 4.26 kWh/m²/day S: 4.57 kWh/m²/day O: 5 kWh/m²/day N: 5.05 kWh/m²/day D: 5.56 kWh/m²/day J F M A M J J A S O N D 7 0
Month GHI Clear-sky DNI DHI Temp °C Humid %
Jan 5.78 8.19 3.84 2.60 25.7 83
Feb 5.97 7.77 4.60 2.34 25.8 82
Mar 5.14 6.88 4.03 2.18 25.4 83
Apr 4.52 5.80 4.42 1.69 24.3 82
May 3.68 4.82 4.06 1.46 22.3 80
Jun 3.46 4.33 4.30 1.24 21.5 80
Jul 3.64 4.59 4.63 1.16 20.9 78
Aug 4.26 5.41 4.89 1.33 21.3 77
Sep 4.57 6.29 4.20 1.66 22.0 77
Oct 5.00 7.32 3.62 2.19 22.9 79
Nov 5.05 8.00 3.06 2.53 23.4 82
Dec 5.56 8.23 3.52 2.61 24.7 84

GHI, Clear-sky, DNI, DHI in kWh/m²/day. Data: NASA POWER climatology (long-term monthly averages).

Off-grid calculator

Add appliances

  • Add an appliance to size a system.

Sizing

Daily load
0.00 kWh
Panel wattage
0 W
Panel count (400W modules)
0
Battery bank
0.0 kWh

Sizing against worst-month PSH of 3.46 kWh/m²/day, 0.77 system efficiency.

About solar in Duque de Caxias

Duque de Caxias, Brazil has a warm, tropical climate with a distinct wet and dry season. Its annual peak sun hours average 4.72 kWh/m²/day, a good solar resource by global standards.

The strongest month in Duque de Caxias is February (summer) at 5.97 kWh/m²/day, and the weakest is June (winter) at 3.46 kWh/m²/day. When sizing a year-round off-grid system, it's standard practice to design against the June value rather than the annual average — otherwise the battery bank runs low during the darkest weeks.

Duque de Caxias's solar conditions are well within the range where off-grid PV is a straightforward engineering exercise with standard-sized arrays and lithium batteries.

FAQ

What are the peak sun hours in Duque de Caxias?
Duque de Caxias averages 4.72 peak sun hours per day annually, ranging from 3.46 in June to 5.97 in February.
How many solar panels do I need in Duque de Caxias?
Panel count depends on your daily load. At Duque de Caxias's annual average of 4.72 kWh/m²/day, a 5 kWh/day load needs roughly 4 × 400 W panels. Use the calculator above for your actual load.
What size battery do I need in Duque de Caxias?
Sizing against Duque de Caxias's worst month (June, 3.46 kWh/m²/day) with 2 days of autonomy at 80% depth of discharge, a 5 kWh/day load needs about a 12.5 kWh battery bank.
How does Duque de Caxias's solar resource compare globally?
Duque de Caxias sits in solar zone 3 out of 5 (where 5 is strongest) at 4.72 kWh/m²/day — good by global standards. For reference, top-tier desert sites average ~6.5 and high-latitude cities around 2.5 kWh/m²/day.
How does the wet season affect solar generation in Duque de Caxias?
Duque de Caxias's dry-season output peaks at 5.97 kWh/m²/day in February; the wet season drops it to 3.46 in June. That ~53% swing is a key sizing consideration.
Can solar panels survive tropical storms in Duque de Caxias?
Most tier-1 PV panels are rated for 140+ mph wind loads; mounting hardware usually fails first. In cyclone-prone regions like Brazil, specify IEC 61215-certified panels and anchor-bolt mounts rather than ballasted.
What's the dry-to-wet output gap in Duque de Caxias?
Duque de Caxias swings from 5.97 kWh/m²/day in February (dry) to 3.46 in June (wet) — roughly 53%. Year-round off-grid systems must size against the wet-season minimum.