peaksunhours.app

Peak Sun Hours in Bhatara, Dhaka Division, Bangladesh

4.5
kWh/m²/day (annual avg)
Solar zone
Zone 3 (good)
Best month
April (5.5)
Worst month
December (3.5)
Climate
Tropical · 25.5°C

Monthly solar breakdown

J: 3.62 kWh/m²/day F: 4.6 kWh/m²/day M: 5.29 kWh/m²/day A: 5.5 kWh/m²/day M: 5.24 kWh/m²/day J: 4.44 kWh/m²/day J: 4.38 kWh/m²/day A: 4.55 kWh/m²/day S: 4.33 kWh/m²/day O: 4.39 kWh/m²/day N: 4.21 kWh/m²/day D: 3.52 kWh/m²/day J F M A M J J A S O N D 7 0
Month GHI Clear-sky DNI DHI Temp °C Humid %
Jan 3.62 4.04 3.22 1.69 17.6 64
Feb 4.60 4.93 4.00 1.95 21.7 54
Mar 5.29 5.84 4.00 2.38 26.7 50
Apr 5.50 6.45 3.30 2.86 29.6 64
May 5.24 6.67 2.60 2.91 29.6 75
Jun 4.44 6.76 1.57 2.83 28.8 87
Jul 4.38 6.99 1.63 2.83 28.4 89
Aug 4.55 6.76 1.85 2.88 28.2 89
Sep 4.33 6.14 2.11 2.62 27.8 89
Oct 4.39 5.42 3.46 2.02 26.1 84
Nov 4.21 4.57 4.53 1.56 22.5 78
Dec 3.52 3.90 3.64 1.48 18.9 74

GHI, Clear-sky, DNI, DHI in kWh/m²/day. Data: NASA POWER climatology (long-term monthly averages).

Off-grid calculator

Add appliances

  • Add an appliance to size a system.

Sizing

Daily load
0.00 kWh
Panel wattage
0 W
Panel count (400W modules)
0
Battery bank
0.0 kWh

Sizing against worst-month PSH of 3.52 kWh/m²/day, 0.77 system efficiency.

About solar in Bhatara

Bhatara, Bangladesh has a warm, tropical climate with a distinct wet and dry season. Its annual peak sun hours average 4.51 kWh/m²/day, a good solar resource by global standards.

The strongest month in Bhatara is April (spring) at 5.5 kWh/m²/day, and the weakest is December (winter) at 3.52 kWh/m²/day. When sizing a year-round off-grid system, it's standard practice to design against the December value rather than the annual average — otherwise the battery bank runs low during the darkest weeks.

Bhatara's solar conditions are well within the range where off-grid PV is a straightforward engineering exercise with standard-sized arrays and lithium batteries.

FAQ

What are the peak sun hours in Bhatara?
Bhatara averages 4.51 peak sun hours per day annually, ranging from 3.52 in December to 5.5 in April.
How many solar panels do I need in Bhatara?
Panel count depends on your daily load. At Bhatara's annual average of 4.51 kWh/m²/day, a 5 kWh/day load needs roughly 4 × 400 W panels. Use the calculator above for your actual load.
What size battery do I need in Bhatara?
Sizing against Bhatara's worst month (December, 3.52 kWh/m²/day) with 2 days of autonomy at 80% depth of discharge, a 5 kWh/day load needs about a 12.5 kWh battery bank.
How does Bhatara's solar resource compare globally?
Bhatara sits in solar zone 3 out of 5 (where 5 is strongest) at 4.51 kWh/m²/day — good by global standards. For reference, top-tier desert sites average ~6.5 and high-latitude cities around 2.5 kWh/m²/day.
How does the wet season affect solar generation in Bhatara?
Bhatara's dry-season output peaks at 5.5 kWh/m²/day in April; the wet season drops it to 3.52 in December. That ~44% swing is a key sizing consideration.
Can solar panels survive tropical storms in Bhatara?
Most tier-1 PV panels are rated for 140+ mph wind loads; mounting hardware usually fails first. In cyclone-prone regions like Bangladesh, specify IEC 61215-certified panels and anchor-bolt mounts rather than ballasted.
What's the dry-to-wet output gap in Bhatara?
Bhatara swings from 5.5 kWh/m²/day in April (dry) to 3.52 in December (wet) — roughly 44%. Year-round off-grid systems must size against the wet-season minimum.